Borehole Exploration Calculator

Borehole Exploration Calculator

Project Information

Reference Tables

Minimum Number of Boreholes Based on Area

Area (m²) Minimum Boreholes
<100 2
250 3
500 4
1000 5
2000 6
5000 7
6000 8
8000 9
10,000 10

Borehole Spacing Guidelines

Project Type Spacing (m)
Multistory buildings 10 – 30
One-story industrial plants 20 – 60

Calculation Methodology

Depth of Exploration (D): Calculated using the formula D = C(S)^0.7 where C is a constant (3 for light steel/narrow concrete, 6 for heavy steel/wide concrete) and S is the number of stories.

Minimum Depth: The greater of (D - D/3) + 1.5B or 1B to 3B for shallow foundations.

Number of Boreholes: Determined based on building area in square meters, following standard guidelines.

Borehole Spacing: Recommended spacing for multistory buildings is 10-30 meters.

Scroll to Top